Categories

LIY(St)Y
 - PVC insulated, screened, data, control and connecting cable Maximize

LIY(St)Y
 - PVC insulated, screened, data, control and connecting cable

LIY(St)Y
 data cable - Construction


Conductor              : flexible copper wires, plain; IEC 60228 Class 5,
                              DIN EN 60228 Class 5.
Insulation               : PVC compound, YI2, VDE 0207-4.
Core identification   : DIN 47100 or DIN EN 50334
                              black cores with white numerals.
Lay-up                   : cores laid up in layers of optimum pitch.
Separator               : polyester tape.
Screen                   : with drain wire under the AL-PES tape.
Outer sheath          : PVC compound, YM1, VDE 0207-5.
Sheath colour         : RAL 7032, Grey.

More details

LIY(St)Y
 data cable - Technical data and tests

Insulation resistance  : Min. 50 MΩ/km.
Mutual capacitance    : d/d-c/c    0,22 mm²: max. 120 pF/m;
                                d/d-c/c ≥ 0,25 mm²: max. 150 pF/m;
                                d/e-c/s     0,22 mm² : max. 240 pF/m;
                                d/e-c/s ≥ 0,25 mm² : max. 270 pF/m.
 
 
 

Inductance              : ~ 0,67 Mh/km;

Impedance              : ~ 80 Ω.
Rated voltage          :    0,22 mm² : 350 V;
                               ≥ 0,25 mm²: 500 V;
                               ≥  0,50 mm²: 300/500 V ( Uo/U ).
Test voltage           :     0,22 mm²: 1200 V;
                               ≥ 0,25 mm² : 1500 V;
                               ≥ 0,50 mm² : 2000 V.
Temperature range : fixed    : - 30° C ~ + 80° C;
                              mobile :   - 5° C ~ + 70° C.
Min. bending radius : fixed    :   6 x D;
                              mobile : 15 x D.

LIY(St)Y
 data cable - Standards
Cable                  : VDE 0812 & VDE 0814 & VDE 0245.

Conductor           : IEC 60228 Class 5, DIN EN 60228 Class 5.

Core identif.        : DIN 47100 or DIN EN 50334

Insulation            : VDE 0207-4.

Outer sheath       : VDE 0207-5.

Flame retardance : IEC 60332-1 & EN 50265-2-1.

LIY(St)Y
 data cable - 
Applications
These screened flexible control and connecting cables are used in instrumentation and control engineering; in industrial electronics, computers, security systems, information and transmission systems, office machines and for voice frequency transmission.
The screen provides protection against external pulses.
These cables are not intended for outdoor or underground installation.