LIYCY data cable - Technical data and tests
Insulation resistance : min. 200 MΩ/km.
Mutual Capacitance : d/d-c/c 0,14 mm² : max. 120 pF/m;
d/d-c/c ≥ 0,25 mm²: max. 150 pF/m.
Inductance : ~ 0,67 Mh/km.
Impedance : ~ 80 Ω.
Rated voltage : 0,14 mm² : 350 V;
≥ 0,25 mm²: 500 V;
≥ 0,50 mm² :300/500 V ( Uo/U ).
Test voltage : 0,14 mm² : 1200 V;
≥ 0,25 mm² : 1500 V;
≥ 0,50 mm² : 2000 V.
Temperature range : fixed : - 30° C ~ + 80° C;
mobile : - 5° C ~ + 70° C.
Min. bending radius : fixed : 6 x D;
mobile: 15 x D.
LIYCY data cable - Standards
Cable standard : VDE 0812 & VDE 0814 & VDE 0245.
Conductor : IEC 60228 Class 5, DIN EN 60228 Class 5.
Insulation : VDE 0207-4.
Core identification : DIN 47100 or DIN EN 50334.
Outer sheath : VDE 0207-5.
Flame retardance : IEC 60332-1 & EN 50265-2-1.
LIYCY data cable - Applications
These screened flexible control and connecting cables are used in instrumentation and control engineering where low current consumption is required and transmission of the data must be continuous; for example, in industrial electronics, voice frequency, information and transmission systems office machines.
Also, having tinned copper wires as screen provides protection against external pulses.