LIYY - PVC insulated, flexible and interconnecting data and control cable Maximize

LIYY - PVC insulated, flexible and interconnecting data and control cable

LIYY data cable - Construction

Conductor           : flexible copper wires, plain.
Insulation            : PVC compound , YI2.
Core identification : black cores with white numerals.
Lay-up                : cores laid up in layers of optimum pitch.
Separator            : polyester tape.
Outer sheath       : PVC compound, YM1.
Sheath colour      : RAL 7032,Grey.

More details

LIYY data cable - Technical data and tests

Insulation resistance      : min. 200 MΩ/km.
Mutual Capacitance       : max. 120 nF/km.

Inductance                  : ~ 0,70 Mh/km.

Impedance                  : ~ 80 Ω.
Rated voltage              :    0,14 mm² : 350 V;
                                   ≥ 0,25 mm² : 500 V.
Temperature range      : fixed    : - 30° C ~ + 80° C;
                                   mobile :   - 5° C ~ + 70° C.
Min. bending radius      : fixed    :   6 x D;
                                   mobile : 15 x D.

LIYY data cable - Standards

Cable standard       : VDE 0812 & VDE 0814 & VDE 0245.

Conductor             : IEC 60228 Class 5, DIN EN 60228 Class 5.

Insulation              : VDE 0207-4.

Core identificaton   : DIN 47100 or DIN EN 50334.

Outer sheath         : VDE 0207-5.

Flame retardance    : IEC 60332-1 & EN 50265-2-1.

LIYY data cable - 
Applications
LIYY non-screened flexible control and interconnecting cables are used in instrumentation and control engineering projects where low current consumption is required, e.g. in industrial electronics, computers, information and transmission systems, office machines and precision machines.
Additionally LIYY cables are suitable for applications in electronic equipment with plug-in systems where control cables are needed in the smallest dimensions.
LIYY cables are not intended for outdoor or underground installation.