Categories

LIHCH - Halogen free, screened, data cable Maximize

LIHCH - Halogen free, screened, data cable

LIHCH data cable - Construction

Conductor            : flexible copper wires, plain.
Insulation             : HFFR compound, HI2.
Core identification : black cores with white numerals.
Lay-up                 : cores laid up in layers of optimum pitch.
Separator            : polyester tape.
Screen                : braid of tinned Cu wires, 85% coverage.
Outer sheath       : HFFR compound, HM2.  
                           HFFR: Halogen-free flame retardant.
Sheath colour      : RAL 7001,Grey (to be agreed upon the shade of grey).

More details

LIHCH data cable - Technical data and tests

Insulation resistance  : min. 200 MΩ/km.
Mutual Capacitance   : d/d-c/c     0,14 mm² : max. 120 pF/m;
                               d/d-c/c ≥ 0,25 mm² : max. 150 pF/m;
                               d/e-c/s     0,14 mm² : max. 240 pF/m;
                               d/e-c/s ≥ 0,25 mm² : max. 270 pF/m.
Inductance              : ~ 0,67 Mh/km.
Impedance              : ~ 80 MΩ.
 

Rated voltage           :    0,14 mm² : 350 V (for peak voltage);
                                ≥ 0,25 mm² : 500 V;
                                ≥ 0,50 mm² : 300/500 V (Uo/U).
Test voltage            :    0,14 mm² : 1200 V;
                               ≥ 0,25 mm² : 1500 V;
                               ≥ 0,50 mm² : 2000 V.
Temperature range  : fixed    : - 30° C ~ + 70° C;
                               mobile :   - 5° C ~ + 50° C.
Min. bending radius  : fixed   :   6 x D;
                              mobile : 12 x D.

LIHCH data cable - Standards
Cable                       : VDE 0812 & VDE 0814 &
  VDE 0245.

Conductor                : IEC 60228 Class 5, 
  DIN EN 60228 Class 5.

Insulation                 : VDE 0207-23.

Core identification     : DIN 47100 or DIN EN 50334.

Outer sheath           : VDE 0207-24.

Flame                      : IEC 60332-3 & DIN EN 50266-2-4.
Smoke density          : IEC 61034-2 & DIN EN 61034-2.
Halogen-free            : IEC 60754-1/2 & DIN EN 50267-2. 


LIHCH data cable - Applications

These halogen-free screened flexible control and connecting cables are used in instrumentation and control engineering where low current consumption is required and transmission of the data must be continuous, for example in industrial electronics, information and transmission systems office machines.
Also, having tinned copper wires as screen provides protection against external pulses. These cables are used at schools, airpots, hospitals, etc. and in the environments which must have no corrosive gases emitted in the event of fire.
In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. These cables are not intended for outdoor or underground installation.

All Rights Reserved Halley Cables © 2006 - 2024