Categories

AC2XH - Aluminium conductor low voltage power cable, with XLPE insulation and PE sheath (LSZH) Maximize

AC2XH - Aluminium conductor low voltage power cable, with XLPE insulation and PE sheath (LSZH)

AC2XH low voltage power cable 0.6/1 kV - Construction


1. Conductor        : aluminium, class 1 or class 2, according to EN 60228.
2. Insulation         : cross-linked polyethylene (XLPE) 2XI1 type,
                            according to HD 604.
3. Internal sheath
4. External sheath : thermoplastic PE with low emission of smoke and
                            corosive gases (HFFR), HM4 type, according to HD 604.

More details

AC2XH low voltage power cable 0.6/1 kV - Technical data and tests

Construction standard                       : VDE 0276-604 (cables type NA2XH). 

Nominal tension Uo /U(Um)               : 0.6 /1 (1.2) kV.

Min. cable temperature (ext. sheath) : installation    :  - 5° C.

                                                      in service       : -40° C.

Max. allowed temp. on conductor,

under optimal functioning conditions  :  +90° C. 

                short circuit (max. 5 s)     :  250° C.

Test voltage                                   : 4 kV, 50 Hz, for 5 minutes.

Flame retardancy                             : EN 50266-2-4, category C and EN 60332-1-2. 

Corosive gases                                : EN 50267-2-2:  pH ≥ 4,3 conductivity  ≤ 100 μS/cm⁻¹.

Smoke density                                : EN 61034 : light permeability ≥ 60%.

Minimum bending radius                   : 15 x external diameter, for monowire cables.
  
                                                     12 x external diameter, for multiwire cables.
 

Conductor symbols                         : ru  - round monowire conductor ( class 1 );

                                                     sm - sector shaped stranded conductor ( class 2 );
                                                     rm - round stranded conductor ( class 2 ).
                                                     Upon request, cables with flexible conductors can be produced (class 5).
 
AC2XH low voltage power cable 0.6/1 kV - Applications

These cables are suited for fixed electrical installations in public buildings, train stations, power stations, metro stations, airports, performance venues, supermarkets, hospitals, etc. When burning, the cables do not release toxic or corosive gases and have low smoke emissions.
Cables with only one conductor must not be used in alternating current.

All Rights Reserved Halley Cables © 2006 - 2024