A2XS(F) 2YT 
 6/10, 12/20, 20/35 kV - Aerial bundled medium voltage power cables with PE sheath Maximize

A2XS(F) 2YT 
 6/10, 12/20, 20/35 kV - Aerial bundled medium voltage power cables with PE sheath

A2XS(F) 2YT 
 6/10, 12/20, 20/35 kV   Aerial bundled medium voltage power cables with PE sheath - Construction
 
Conductor                        : round, stranded and compacted alum., class 2.

Inner semi-conductive layer : XLPE compound.

Insulation                         : XLPE type XI 1.

Outer semi-conductive layer : XLPE comp. around insulation.

Water resistant element       : layer of semi-conductive water absorbing tape.

Metal screen                      : CU wires conc. laid and one contact of CU tape.

Water resistant element       : layer of semi-conductive water absorbing tape.

PE sheath                         : PE compound, type EP 1.
Messenger (for 10, 20 kV)   : galvanized steel messenger 50 mm². 
Messenger (for 35 kV)        : galvanized steel messenger 70 mm².

More details

A2XS(F) 2YT 
 6/10, 12/20, 20/35 kV   Aerial bundled medium voltage power cables with PE sheath - Technical data and tests
 
Operating voltage                           : 6/10; 12/20; 20/35 kV.

Test voltage = 2.5Uo (HD.620.S2),
                      
 AC (50Hz) - 5 min   :   6/10 kV = 15 kV;
  12/20 kV = 30 kV;
  20/35 kV = 50 kV.

Highest system voltage, Umax          :   6/10 kV = max. 12 kV;
  12/20 kV = max. 24 kV;
  20/35 kV = max. 40 kV.
Conductor resistance at 20o C          : according to EN 60228 class 2.

Core temperature, max                    : 90° C in continuous operation.

Max. short circuit temperature          : 250° C , not more than 5 sec.

Overload temperature                      : 130° C / 100h per year max.

Level of partial discharge                 : no more than 2pC.

Bending radius, min                       : 15 x D.

Dielectric factor of losses, 50 Hz       : at 20°C, (0.8-3)x10-4.

Spec.volume insulation resistance     : at 20°C, min 1015 Ω x cm.

Intensity of electric field                  : max. 6.9-5.3 kV/mm.

Max. tensile force during laying        : for Cu conductors - 50 N/mm².

                                                    for Al conductors - 30 N/mm².

Breaking load of messenger, min      : for 50 mm2 = 60 kN.
  for 70 mm² = 82 kN.

Modulus of elasticity of messenger    : 175 kN/mm²
.
Packing length on wooden drums     : min. 200 m.
 
A2XS(F) 2YT 
 6/10, 12/20, 20/35 kV   Aerial bundled medium voltage power cables with PE sheath -Available constructions
 

Single Al core                            : 1x(25 - 150)mm²

Standard cross section of metallic

 screen for conductor sizes          :

from 25   mm² to 120 mm²        : 16mm²;

from 150 mm² to 300 mm²        : 25mm²;

from 400 mm² to 630 mm²        : 35mm².
 
A2XS(F) 2YT 
 6/10, 12/20, 20/35 kV   Aerial bundled medium voltage power cables with PE sheath - Standards
 
Cable                            : HD 620.S2, IEC 60502-2, SRPS N.C5.231.

Messenger                     : HD 620.S2.

Conductors                    : EN 60228.

Conductor shape            : RM - class 2 conductor acc. to IEC 60228 and VDE 0295.

Inner sheath                  : N.C0.195.

Water penetration in the

region of metallic screen  : IEC 60502-2 annex F (125x4h, 90°C).
 
A2XS(F) 2YT 
 6/10, 12/20, 20/35 kV   Aerial bundled medium voltage power cables with PE sheath - Applications
 
These cables are suitable for medium voltage power distribution in distribution networks (6/10(12);12/20(24) kV).
They may be put on the overhead lines in old and residential areas.
Provides a shortcut to electrification without affecting the townscape and its environs.
These cables can be strung safely on the same poles with low-voltage and telecommunication cables and have water resistant properties.