Categories

H01N2-D/-E
 - Arc welding cable with normal and improved flexibilty Maximize

H01N2-D/-E
 - Arc welding cable with normal and improved flexibilty

H01N2-D/-E
 arc welding rubber cable - Construction
 

Conductor            : bare copper.

Sheating material   : rubber (CR) EM5.

More details

H01N2-D/-E
 arc welding rubber cable - Technical data and tests
Rated voltage Uo/U                        : 100/100 V.

Test voltage                                  : 1 kV.

Max. temperature at conductor        : 85° C.

Max. operating temperature, fixed    : -20 ~ +85° C.

Protective conductor                      : no.

Flame retardant                              : yes.

H01N2-D                                       : cable with normal flexibility.

H01N2-E                                       : cable with high flexibility.
 
H01N2-D/-E
 arc welding rubber cable - Standards

Cable                     : EN 50525-2-81.

Core identification    : VDE 0293 (HD308); more than 5 cores: gn-ye + numbers.

Flame retardant       : VDE 0482-332-1-2/IEC 60332-1
.
Oil resistant             : EN 660811-2-1.

H01N2-D/-E
 arc welding rubber cable -Applications

For portable electrode-carriers use.
It is crucial to follow the table's data of the user guide CEI 20-40 in merit to the service cycles, the intensities of current and the voltage fall.
In order to reduce the effects of the alternating current on the voltage fall, the cables forming the welding circuit must be maintained as close as possible.

All Rights Reserved Halley Cables © 2006 - 2024