Categories

H07ZZ-F
 - Flexible rubber cable(cord) insulated and sheathed with halogen-free
 L.S.O.H. thermoplastic compounds Maximize

H07ZZ-F
 - Flexible rubber cable(cord) insulated and sheathed with halogen-free
 L.S.O.H. thermoplastic compounds

H07ZZ-F rubber cable - Construction
 

Conductor      : flexible conductor bare or tinned copper, class 6.

Insulation       : paper tape.

Outer sheath   : polychloroprene sheath, EM2.
Sheath colour : black.

More details

H07ZZ-F rubber cable - Technical data and tests
Rated voltage Uo/U                    : 100/100 V.

Test voltage                              : 1000 V.

Maximum operating temperature   : +85° C.

Max. short circuit temperature      : +250° C; -20° C.

Min. operating temperature          : -35° C.

Min. installation and use temp.     : -20° C.

Max. pulling stress                      : 50 N/mm² (during installation, when the cable is pulled, it must not revolve around its axis).
 
H07ZZ-F rubber cable - Standards
Cable: BT 2006/95/EC-RoHS:2002/95/EC.

CEI EN 50525-3-21 CEI 20-107/3-21.

CEI EN 60332-1 (CEI 20-35).

CEI EN 60332-3-24 (CEI 20-22 III).

CEI EN 50267.
 
H07ZZ-F rubber cable - Applications

For portable electrode-carriers use.
It's crucial to follow the table's data of the user guide CEI 20-40 regarding the service cycles, the intensities of current and the voltage fall.
In order to reduce the effects of the alternating current on the voltage fall, the cables forming the welding circuit must be kept as close as possible.