 - PVC insulated and sheathed instrumentation cable 500 V
 
Construction
 
Conductor           : plain copper wire, stranded.

Insulation            : PVC compound, 70° C.
PIMF construction : polyester tape the pair above, AL-PES tape
                           over solid tinned copper drain wire, 0,60 mm.
Separator            : polyester tape.
Screen                : AL-PES tape over stranded tinned copper drain
                           wire 0,50 mm².

Inner sheath        : PVC compound 70° C.

Armour               : galvanized round steel wire.

Outer sheath        : PVC compound, 70° C.
Sheath colour      : RAL 9005, black or RAL 5015, blue.

 
*Please check the data sheet for detailed information.

More details

RE-Y(St)YSWAY-fl-PIMF   70° C - CU/PVC/ISCR/OSCR/PVC/SWA/PVC
 - PVC insulated and sheathed instrumentation cable 500 V
 
Technical data and test


Rated voltage          : 500 V.

Test voltage            : Urms core-core    : 2000 V;
                            
  Urms core-screen : 2000 V.
Temperature range   : operation : - 30° C ~ + 70° C;
                              installation : - 5° C ~ + 50° C.
Min. bending radius  : 10 x D.

Insulation resistance : min. 100 MΩ/km.

RE-Y(St)YSWAY-fl-PIMF   70° C - CU/PVC/ISCR/OSCR/PVC/SWA/PVC
 - PVC insulated and sheathed instrumentation cable 500 V

Technical data and tests

Conductor resistance : 0,50 mm² : 36,7 Ω/km;
                               0,75 mm² : 25,0 Ω/km;
                                 1,0 mm² : 18,5 Ω/km;
                                 1,3 mm² : 14,2 Ω/km;
                                 1,5 mm² : 12,3 Ω/km.
Mutual Capacitance : 0,50 mm² : max. 160 pF/m;
                             0,75 mm² : max. 160 pF/m;
                               1,0 mm² : max. 160 pF/m;
                               1,3 mm² : max. 170 pF/m;
                               1,5 mm² : max. 170 pF/m.
L / R (ratio) (max.) : 0,50 mm² : 25 µH/Ω;
                             0,75 mm² : 25 µH/Ω;

                               1,0 mm² : 25 µH/Ω;

                               1,3 mm² : 40 µH/Ω;

                               1,5 mm² : 40 µH/Ω; 

RE-Y(St)YSWAY-fl-PIMF   70° C - CU/PVC/ISCR/OSCR/PVC/SWA/PVC
 - PVC insulated and sheathed instrumentation cable 500 V

Standards

Design                    : DIN EN 50288-7.

Insulation                : EN 50290-2-21.

Conductor               : IEC 60228 class 2, DIN EN 60228 class 2.

Inner sheath             : EN 50290-2-22.

Armour                    : EN 10257-1.

Outer sheath             : EN 50290-2-22.

Flame retardance test : IEC 60332-1 & EN 60332-1.
 
RE-Y(St)YSWAY-fl-PIMF   70° C - CU/PVC/ISCR/OSCR/PVC/SWA/PVC
 - PVC insulated and sheathed instrumentation cable 500 V
 
Applications

These instrumentation cables are used for the transmission of digital and analogue signals in instrument and control systems at chemistry and petrochemistry plants, power plants, natural gas and petroleum plants, etc... .
Instrumentation cables are not allowed to be directly connected to low impedance sources, e.g. public mains electricity supply.
For applications at 105° C heat, RE-Yw(St)YwSWAYw-PIMF cables are suitable.
With blue sheath it is suitable for naturally safe systems.
The armour above the inner sheath protects the cable from mechanical shocks.
These cables are recommended for direct burial.
They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits.

All Rights Reserved Halley Cables © 2006 - 2024