Categories

RE-Y(St)YSWAY-fl  70° C - CU/PVC/OSCR/PVC/SWA/PVC
 Maximize

RE-Y(St)YSWAY-fl 70° C - CU/PVC/OSCR/PVC/SWA/PVC


RE-Y(St)YSWAY-fl  70° C - CU/PVC/OSCR/PVC/SWA/PVC
 - PVC insulated instrumentation cable 500 V
 
Construction

Conductor      : plain copper wire, stranded.

Insulation       : PVC compound, 70° C.
Pair               : two conductors twisted to a pair.
Separator       : polyester tape.
Screen           : AL-PES tape over stranded tinned
                      copper drain wire 0,50 mm².

Inner sheath   : PVC compound 70° C.

Armour          : galvanized round steel wire.

Outer sheath   : PVC compound, 70° C.
Sheath colour : RAL 9005, black or RAL 5015, blue.

*Please check the data sheet for detailed information.

More details

RE-Y(St)YSWAY-fl  70° C - CU/PVC/OSCR/PVC/SWA/PVC
 - PVC insulated instrumentation cable 500 V
 
Technical Data and Tests
 

Rated voltage                     : 500 V.

Test voltage                       : Urms core-core    : 2000 V;
                                       
  Urms core-screen : 2000 V.
Temperature range              : operation : - 30° C ~ + 70° C;
                                         installation : - 5° C ~ + 50° C.
Min. bending radius             : 10 x D.

Insulation resistance (20° C) : min. 100 MΩ/km.
 
RE-Y(St)YSWAY-fl  70° C - CU/PVC/OSCR/PVC/SWA/PVC
 - PVC insulated instrumentation cable 500 V
 
Technical data and tests

Conductor resistance : 0,50 mm² : 36,7 Ω/km;
                               0,75 mm² : 25,0 Ω/km;
                                 1,0 mm² : 18,5 Ω/km;
                                 1,3 mm² : 14,2 Ω/km;
                                 1,5 mm² : 12,3 Ω/km.
Mutual capacitance  : 0,50 mm² : max. 160 pF/m;
                              0,75 mm² : max. 160 pF/m;
                                1,0 mm² : max. 160 pF/m;
                                1,3 mm² : max. 170 pF/m;
                                1,5 mm² : max. 170 pF/m.
L / R (ratio) (max.)  : 0,50 mm² : 25 µH/Ω;
                              0,75 mm² : 25 µH/Ω;
                            
    1,0 mm² : 25 µH/Ω;

                                1,3 mm² : 40 µH/Ω;
                            
    1,5 mm² : 40 µH/Ω; 
 
RE-Y(St)YSWAY-fl  70° C - CU/PVC/OSCR/PVC/SWA/PVC
 - PVC insulated instrumentation cable 500 V
 
Standards
 

Design                   : DIN EN 50288-7.

Conductor              : IEC 60228 class 2, DIN EN 60228 class 2.

Insulation               : EN 50290-2-21.

Inner sheath            : EN 50290-2-22.

Armour                   : EN 10257-1.

Outer sheath            : EN 50290-2-22.

Flame retardance test : IEC 60332-1 & EN 60332-1.
 
RE-Y(St)YSWAY-fl  70° C - CU/PVC/OSCR/PVC/SWA/PVC
 - PVC insulated instrumentation cable 500 V
 
Applications
 
These cables are used for transmission of analogue and digital signals in instrumentation and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroleum plants, etc... .
Instrumentation cables are not allowed for direct connection to a low impedance source, e.g. public mains electricity supply.
With blue sheath it is suitable for intrinsically safe systems.
These cables are not recommended for direct burial.
They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits.

All Rights Reserved Halley Cables © 2006 - 2024