RE-2Y(St)Y-fl   70° C
 - CU/PE/OSCR/PVC Maximize

RE-2Y(St)Y-fl 70° C
 - CU/PE/OSCR/PVC

RE-2Y(St)Y-fl   70° C
 - CU/PE/OSCR/PVC - Single and multi-triple, PE insulated, collective screened, PVC sheathed instrumentation cable 300/500 V
 
Construction
 

Conductor            : plain annealed copper wire, BS 6360;
                            0,50 mm² and 1,0 mm² solid, 0,50 mm² and
                            0,75 mm² flexible or 1,5 mm² stranded.   

Insulation             : PE compound, BS 6234 Type 03.
Triple                   : three conductors twisted to a pair.

Lay-up                 : triples laid up in layers of optimum pitch.

Separator             : polyester tape.

Screen                 : AL-PES tape over tinned copper drain wire 0,50 mm².

Outer sheath        : PVC compound, flame retardant; TM1, BS 7655.

Sheath colour       : RAL 9005, black or RAL 5015, blue.

More details

RE-2Y(St)Y-fl   70° C
 - CU/PE/OSCR/PVC - Single and multi-triple, PE insulated, collective screened, PVC sheathed instrumentation cable 300/500 V
 
Technical data and tests

Rated voltage (Uo/U)    : 300/500 V.

Test voltage                 : Urms core-core    : 1000 V;

                                     Urms core-screen : 1000 V.

Temperature range       : operation : - 40° C ~ + 70° C;
                                  
   installation : - 5° C ~ + 50° C.

Capacitance unbalanced : (1 kHz) : max. 250 pF/250 m.

Insulation resistance      : min. 5000 MΩ/km.
Min. bending radius       : 6 x D.

L/R (ratio) (max)          : 0,50 mm² : 25 µH/Ω;
                                   
  0,75 mm² : 25 µH/Ω;

                                       1,0 mm² : 25 µH/Ω;
                                   
    1,5 mm² : 40 µH/Ω.
 
RE-2Y(St)Y-fl   70° C
 - CU/PE/OSCR/PVC - Single and multi-triple, PE insulated, collective screened, PVC sheathed instrumentation cable 300/500 V
 
Technical data and tests
 
Insulation thickness         : 0,50 mm² : 0,50 mm;
                                         1,0 mm² : 0,60 mm;

                                       0,50 mm² : 0,60 mm;
                                     
  0,75 mm² : 0,60 mm;
                                       1,50 mm² : 0,60 mm.

Conductor class, BS 6360  : 0,50 mm² : Class 1;
                                      
    1,0 mm² : Class 1;
                                      
  0,50 mm² : Class 5;
                                        0,75 mm² : Class 5;
                                        1,50 mm² : Class 2.

Conductor resistance        : 0,50 mm² : 36,8 Ω/km;

                                          1,0 mm² : 18,4 Ω/km;
                                        0,50 mm² : 39,7 Ω/km;
                                        0,75 mm² : 26,5 Ω/km;
                                        1,50 mm² : 12,3 Ω/km.

Mutual capacitance (1 kHz) :      ≤2 pairs                  all other pairs

                                  0,50  mm² : max. 115 pF/m,  max. 75 pF/m;
                                  0,75  mm² : max. 115 pF/m,  max. 75 pF/m;
                                     1,0 mm² : max. 115 pF/m,  max. 75 pF/m;

                                     1,5 mm² : max. 120 pF/m,  max. 85 pF/m.
 
RE-2Y(St)Y-fl   70° C
 - CU/PE/OSCR/PVC - Single and multi-triple, PE insulated, collective screened, PVC sheathed instrumentation cable 300/500 V
 
Standards
 

Design                 : BS 5308 Part 1 Type 1.

Conductor            : BS 6360.

Insulation            : BS 6234 Type 03.

Outer sheath        : BS 7655.

Flame retardancy : IEC 60332-1 & BS EN 60332-1;
                             IEC 60332-3 & BS EN 50266-2-4.
 
RE-2Y(St)Y-fl   70° C
 - CU/PE/OSCR/PVC - Single and multi-triple, PE insulated, collective screened, PVC sheathed instrumentation cable 300/500 V
 
Applications

These cables are used for transmission of analogue and digital signals in instrument and control systems at chemistry and petrochemistry industry
 plants, power plants, natural gas and petroleum plants, etc.
Instrumentation cables are not allowed for direct connection to a low impedance 
sources, e.g. public mains electricity supply.
With blue sheath it is suitable for intrinsically safe systems.
These cables are not recommended for
 direct burial.
They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits.