Categories

RE-Y(St)YSWAY-fl-PIMF 70° C
 - CU/PVC/ISCR/OSCR/PVC/SWA/PVC Maximize

RE-Y(St)YSWAY-fl-PIMF 70° C
 - CU/PVC/ISCR/OSCR/PVC/SWA/PVC

RE-Y(St)YSWAY-fl-PIMF 70° C
 - CU/PVC/ISCR/OSCR/PVC/SWA/PVC - PVC insulated, screened, 
armoured, PVC sheathed instrumentation cable 300/500 V
 
Construction

Conductor            : plain annealed copper wire, BS 6360 0,50 mm² and
                             0,75 mm² flexible, or 1,5 mm² stranded.

Insulation             : PVC compound, TI1, BS 6746.

Separator             : polyester tape.

Screen                 : AL-PES tape over tinned copper drain wire.

Bedding               : PVC compund, TM1, BS 7655, black.

Armour                : galvanized round steel wire, BS EN 10257-1.

Outer sheath        : PVC compound, flame retardant; TM1, BS 7655.

Sheath colour       : RAL 9005, back.

More details

RE-Y(St)YSWAY-fl-PIMF 70° C
 - CU/PVC/ISCR/OSCR/PVC/SWA/PVC - PVC insulated, screened, 
armoured, PVC sheathed instrumentation cable 300/500 V
 
Technical Data and Tests

Rated voltage  (U°/U)           : 300/500 V.

Insulation resistance (20° C) : min. 25 MΩ.km.

Mutual capacitance (1 kHz)   : max. 250 pF/m.
Capacitance unbalanced       : (1 kHz) : max. 450 pF/250 m.


Test voltage                        : Urms core-core : 1000 V;  
                                          Urms core-screen : 1000 V.

Temperature range              : operation  : - 40° C ~ + 70° C;
                                         installation :  - 5° C ~ + 50° C.

Min. bending radius             : 6 x D.


RE-Y(St)YSWAY-fl-PIMF 70° C
 - CU/PVC/ISCR/OSCR/PVC/SWA/PVC - PVC insulated, screened, 
armoured, PVC sheathed instrumentation cable 300/500 V
 
Standards

Design              : BS 5308 Part 2 Type 1.

Conductor         : BS 6360.

Insulation          : BS 6746.

Armour              : BS EN 10257-1.
Outer sheath       : BS 7655.

Flame retardancy : IEC 60332-1 & BS EN 60332-1.
 
RE-Y(St)YSWAY-fl-PIMF 70° C
 - CU/PVC/ISCR/OSCR/PVC/SWA/PVC - PVC insulated, screened, 
armoured, PVC sheathed instrumentation cable 300/500 V
 
Applications

These cables are used for transmission of analogue and digital signals in instrument and control systems at chemistry and petrochemistry industry 
plants, power plants, natural gas and petroleum plants, etc... .
Instrumentation cables are not allowed for direct connection to a low impedance 
source, e.g. public mains electricity supply.
These cables are not recommended for direct burial.
They are for indoor and outdoor installation, 
in dry and wet locations; on racks, trays, in conduits.

All Rights Reserved Halley Cables © 2006 - 2024