Categories

RE-2Y(St)Y-fl-TIMF 70° C - CU/PE/ISCR/OSCR/PVC Maximize

RE-2Y(St)Y-fl-TIMF 70° C - CU/PE/ISCR/OSCR/PVC

RE-2Y(St)Y-fl-TIMF 70° C - CU/PE/ISCR/OSCR/PVC - PE insulated, screened, PVC sheathed instrumentation cable 300/500 V
 
Construction


Conductor            : plain annealed copper wire.

Insulation             : PE compound.
Core identification : black / white / red; with numbered tape under
                             separator tape of the pair screen.


TIMF construction : polyester tape above the triple, AL-PES tape over
                             tinned copper drain wire, 0,50 mm².
Separator             : polyester tape.

Screen                 : AL-PES tape over tinned copper drain wire 0,50 mm².

Outer sheath        : PVC compound, flame retardant.
Sheath colour       : RAL 9005, black or RAL 5015, blue.

More details

RE-2Y(St)Y-fl-TIMF 70° C - CU/PE/ISCR/OSCR/PVC - PE insulated, screened, PVC sheathed instrumentation cable 300/500 V
 
Technical data and tests

Rated voltage  (U°/U)           : 300/500 V.

Insulation resistance (20° C)  : min. 5000 MΩ/km. 
Capacitance unbalanced        : (1 kHz) : max. 250 pF/250 m. 
Test voltage                         : Urms core-core : 1000 V;  
                                            Urms core-screen : 1000 V.

Temperature range               : operation : - 40° C ~ + 70° C;  
                                          installation : - 5° C ~ + 50° C.

Min. bending radius              : 6 x D.

 
RE-2Y(St)Y-fl-TIMF 70° C - CU/PE/ISCR/OSCR/PVC - PE insulated, screened, PVC sheathed instrumentation cable 300/500 V
 
Standards


Design                    : BS 5308 Part 1 Type 1.

Conductor               : BS 6360.

Insulation                : BS 6234 Type 03.

Outer sheath            : BS 7655.

Flame retardancy test : IEC 60332-1 & BS EN 60332-1.
 
RE-2Y(St)Y-fl-TIMF 70° C - CU/PE/ISCR/OSCR/PVC - PE insulated, screened, PVC sheathed instrumentation cable 300/500 V
 
Applications


These cables are used for transmission of analogue and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroleum plants, etc... .
Instrumentation cables are not allowed for direct connection to a low impedance source, e.g. public mains electricity supply.
With blue sheath they are suitable for intrinsically safe systems.
These cables are not recommended for direct burial.
They are tor indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits.