RE-2Y(St)2YSWAY-fl-TIMF 70° C - CU/PE/ISCR/OSCR/PE/SWA/PVC Maximize

RE-2Y(St)2YSWAY-fl-TIMF 70° C - CU/PE/ISCR/OSCR/PE/SWA/PVC

RE-2Y(St)2YSWAY-fl-TIMF 70° C - CU/PE/ISCR/OSCR/PE/SWA/PVC - PE insulated, screened, armoured, PVC sheathed instrumentation cable 300/500 V
 
Construction

Conductor            : plain annealed copper wire.

Insulation             : PE compound.
TIMF construction : polyester tape above the triple, AL-PES tape over
                            tinned copper drain wire, 0,50 mm²
Separator             : polyester tape
Screen                 : AL-PES tape over tinned copper drain wire
Bedding               : PE compound.

Armour                : galvanized round steel wire.
Outer sheath        : PVC compound, flame retardant.
Sheath colour       : RAL 9005, black or RAL 5015, blue.

More details

RE-2Y(St)2YSWAY-fl-TIMF 70° C - CU/PE/ISCR/OSCR/PE/SWA/PVC - PE insulated, screened, armoured, PVC sheathed instrumentation cable 300/500 V
 
Technical data and tests

Rated voltage (U°/U)            : 300/500 V.
Test voltage                        : Urms core-core : 1000 V;
                                          Urms core-screen : 1000 V.

Temperature range               : operation : - 40° C ~ + 70° C;
                                          installation : - 5° C ~ + 50° C.

Min. bending radius             : 8 x D.

Capacitance unbalanced       : (1 kHz) : max. 250 pF/250 m.
Insulation resistance (20° C) : min. 5000 MΩ/km.
 
RE-2Y(St)2YSWAY-fl-TIMF 70° C - CU/PE/ISCR/OSCR/PE/SWA/PVC - PE insulated, screened, armoured, PVC sheathed instrumentation cable 300/500 V

Standards


Design              : BS 5308 Part 1 Type 2.

Conductor         : BS 6360.

Insulation          : BS 6234 Type 03.

Armour              : BS EN 10257-1.

Bedding             : BS 6234 Type 3.

Outer sheath       : BS 7655.

Flame retardancy : IEC 60332-1 & BS EN 60332-1.
 
RE-2Y(St)2YSWAY-fl-TIMF 70° C - CU/PE/ISCR/OSCR/PE/SWA/PVC - PE insulated, screened, armoured, PVC sheathed instrumentation cable 300/500 V
 
Applications


This cable is used for transmission of analogue and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroleum plants, etc. Instrumentation cables are not allowed for direct connection to low impedance source, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. This cable is recommended for direct burial. It is suitable for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits.