Categories

RE-2X(St)YSWAYÖ-uv-fl PIMF 70° C - CU/XLPE/ISCR/OSCR/PVC/SWA/PVC Maximize

RE-2X(St)YSWAYÖ-uv-fl PIMF 70° C - CU/XLPE/ISCR/OSCR/PVC/SWA/PVC

RE-2X(St)YSWAYÖ-uv-fl PIMF 70° C - CU/XLPE/ISCR/OSCR/PVC/SWA/PVC - XLPE insulated, armoured, PVC sheathed instrumentation cable 500 V
 
Construction

Conductor                 : plain copper wire, stranded.
Insulation                  : XLPE compound.
Core identification      : black / white with numbered tape under
                                 the separator tape of the pair screen.

PIMF Construction      : polyester tape above the pair.
Separator                  : polyester tape.

Screen                      : AL-PES tape over tinned copper drain wire.

Inner sheath              : PVC compound.
Armour                     : galvanized round steel wire.
Outer sheath             : PVC compound, UV and oil resistant.

Sheath colour            : RAL 5015, blue.

More details

RE-2X(St)YSWAYÖ-uv-fl PIMF 70° C - CU/XLPE/ISCR/OSCR/PVC/SWA/PVC - XLPE insulated, armoured, PVC sheathed instrumentation cable 500 V
 
Technical Data and Tests


Rated voltage              : 500 V. 

Test voltage                : Urms core-core    : 2000 V;

                                    Urms core-screen : 2000 V.

Temperature range       : operation  : - 30° C ~ + 70° C;
                                     installation :  - 5° C ~ + 50° C.
Min. bending radius       : 10 x D.

 
RE-2X(St)YSWAYÖ-uv-fl PIMF 70° C - CU/XLPE/ISCR/OSCR/PVC/SWA/PVC - XLPE insulated, armoured, PVC sheathed instrumentation cable 500 V

Technical data and tests

Conductor resistance (20° C) : 0,50 mm² : 36,7 Ω/km;

                                             0,75 mm² : 25,0 Ω/km;

                                               1,0 mm² : 18,5 Ω/km;  
                                               1,3 mm² : 14,2 Ω/km;

                                               1,5 mm² : 12,3 Ω/km.  

Insulation resistance (20° C) : min. 5000 MΩ/km.

Mutual capacitance (1 kHz)   :  max. 100 pF/m.
L/R (ratio) (max)                 : 0,50 mm² : 25 µH/Ω;

                                            0,75 mm² : 25 µH/Ω;
  
                                              1,0 mm² : 25 µH/Ω;

                                              1,3 mm² : 40 µH/Ω;   

                                              1,5 mm² : 40 µH/Ω.
 
RE-2X(St)YSWAYÖ-uv-fl PIMF 70° C - CU/XLPE/ISCR/OSCR/PVC/SWA/PVC - XLPE insulated, armoured, PVC sheathed instrumentation cable 500 V

Standards
 
Design                       : DIN EN 50288-7.

Conductor                  : IEC 60228 class 2, DIN EN 60228 class 2.

Insulation                   : EN 50290-2-29.

Inner sheath               : EN 50290-2-22.

Armour                      : EN 10257-1.

Flame retardancy test : IEC 60332-1 & EN 60332-1.
Sunlight resistance      : UL 1581 section 1200.
Oil resistance              : ICEA S-82-552.
 
RE-2X(St)YSWAYÖ-uv-fl PIMF 70° C - CU/XLPE/ISCR/OSCR/PVC/SWA/PVC - XLPE insulated, armoured, PVC sheathed instrumentation cable 500 V
 
Applications


These cables are used for transmission of analogue and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroleum plants, etc... .
Instrumentation cables are not allowed for direct connection to a low impedance source, e.g. public mains electricity supply.
With blue sheath it is suitable for intrinsically safe systems.
The armour above the inner sheath protects the cable from mechanical shocks.
These cables are recommended for direct burial.
They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits.

All Rights Reserved Halley Cables © 2006 - 2024