 - Construction


Conductor     : class 5 flexible copper.
Insulation      : HEPR having G7 quality*.
Filler              : non fibrous and non hygroscopic.
Outer sheath : PVC sheath in RZ/ST2 quality.

Colour           : light grey RAL 7035
FG7R    - for one core cables.
  
FG7OR - for multiple cores cables.

* G7 - Suitable for cables showing high electrical and mechanical performances, fire resistance, LS0H cable core. Working temperature: -60 + 90°C. This compound is halogen free.

More details

FG7R / FG7OR - Technical data and tests
Standards                              : according to BT 2006/95/EC- RoHS: 2002/95/EC;
  CEI 20-13 IEC 60502-1;  
                                             CEI UNEL 35375-35377; CEI 20-22 II;
  CEI EN 60332-1-2;  CEI EN 50267-2-1.

Nominal voltage Uo/U              : 600 /1000 V (AC) & 1800 V (DC) - for both 600 and 1000 V.

Test voltage (50 Hz)               : 4000 V.

Maximum voltage Um              : 1200 V (AC) & 1800 V (DC).

Max. operating temperature     : 90° C.

Max. short circuit temperature

for sections up to 240 mm²     : 250° C.

Max. short circuit temperature

for sections over 240 mm²       : 220° C.

Min. operating temperature

(without mechanical shocks)     : -15° C.

Min. installation and use temp.  : 0° C.

Minimum bending radius 
per
D cable diameter (in mm)         : flexible power cables,  class 5 : 4 x D;
  
                                              flexible control cables, class 5 : 6 x D.

Maximum pulling stress             : 50 N/mm².

Core colours                           : single core   : black;
                                              two cores   : blue-brown;
                                              three cores : brown-black-gray (or blue-brown-Y/G);
                                              four cores   : blue-brown-black-gray (or Y/G instead blue);
                                              five cores    : Y/G-blue-brown-black-gray (or black instead Y/G);
                                              multicores   : black with numbers.

FG7R / FG7OR - Applications
This power and control cable can be used in outdoor and indoor applications, even wet.
It is suitable for fixed installations in open air, tubes or canals, masonry, metals structures, overhead wire and for direct or indirect underground wiring.