English
Categories
items: 6 10 20 50
Sort by -- Product Name: A to Z Product Name: Z to A
Show 6 10 20 50 Products by page
These 75 ohm coaxial cables are used as connection cable in CATV, CCTV, satellite and common antenna TV systems for which low attenuation is required.
These 50 ohm coaxial cables are used as connection cable in CATV, CCTV, satellite and common antenna TV systems for which low attenuation is required.
RE-2X(St)YSWAY-fl 90° C - CU/XLPE/OSCR/PVC/SWA/PVC - XLPE insulated armoured, PVC sheathed instrumentation cable 300 V ConstructionConductor : plain copper wire, stranded. Insulation : XLPE compound, (RE-2X….). Core identification : black / white / red cores are numbered (1-1-1, 2-2-2,…).Triple : three conductors twisted to a triple. Lay-up : triples laid up in layers of optimum pitch. Separator : polyester tape. Screen : AL-PES tape over tinned copper drain wire 0,50 mm². Inner sheath : PVC compound, flame retardant. Armour : galvanized round steel wire. Outer sheath : PVC compound, 90° C. Sheath colour : RAL 9005, black or RAL 5015, blue.
RE-2X(St)YSWAY-fl-TIMF 90° C - CU/XLPE/ISCR/OSCR/PVC/SWA/PVC - XLPE insulated, screened, armoured, PVC sheathed instrumentation cable 300 V ConstructionConductor : plain copper wire, stranded. Insulation : XLPE compound, (RE-2X….).TIMF Construction : polyester tape above the pair, AL-PES tape over solid tinned copper drain wire, 0,60 mm. Separator : polyester tape. Screen : AL-PES tape over tinned copper drain wire 0,50 mm². Inner/outer sheath : PVC compound, flame retardant/90° C. Armour : galvanized round steel wire.Sheath colour : RAL 9005, black or RAL 5015, blue. * Please refer to the data sheet for complete information about this cable.
RE-Yw(St)Yw-fl PIMF 105° C - CU/PVC/ISCR/OSCR/PVC - Multi-pair, PVC insulated, screened, PVC sheathed instrumentation cable 300 V ConstructionConductor : plain copper wire, stranded. Insulation : PVC compound, 105° C. Pair : two conductors twisted to a pair.PIMF construction : polyester tape above the pair, AL-PES tape over solid tinned copper drain wire, 0,60 mm. Separator : polyester tape.Screen : AL-PES tape over stranded tinned copper drain wire 0,50 mm². Outer sheath : PVC compound, 105° C. Sheath colour : RAL 9005, black or RAL 5015, blue. * Please refer to the data sheet for complete information about this cable.
RE-Yw(St)Yw-fl 105° C - CU/PVC/OSCR/PVC - Single & multi-triple, PVC insulated, screened, PVC sheathed instrumentation cable 300 V Construction Conductor : plain copper wire, stranded. Insulation : PVC compound, 105° C. Core identification : black / blue / red cores are numbered (1-1-1, 2-2-2,…). Upon request : colour coded according to IEC 60189-2.Triple : three conductors twisted to a triple.Lay-up : triples laid up in layers of optimum pitch.Separator : polyester tape.Screen : AL-PES tape over stranded tinned copper drain wire 0,50 mm². Outer sheath : PVC compound, 105° C. Sheath colour : RAL 9005, black or RAL 5015, blue.
RE-Yw(St)Yw-fl MP 105° C - CU/PVC/OSCR/PVC - Single & multi-pair, PVC insulated, screened, PVC sheathed instrumentation cable 300 V Construction Conductor : plain copper wire, stranded. Insulation : PVC compound, 105° C. Core identification : black / white cores numbered 1-1, 2-2,…Pair : two conductors twisted to a pair.Lay-up : pairs laid up in layers of optimum pitch.Separator : polyester tape.Screen : AL-PES tape over stranded tinned copper drain wire 0,50 mm². Outer sheath : PVC compound, 105° C. Sheath colour : RAL 9005, black or RAL 5015, blue.
RE-Yw(St)Yw-fl-TIMF 105° C - CU/PVC/ISCR/OSCR/PVC/SWA/PVC - PVC insulated, screened, PVC sheathed instrumentation cable 300 V Construction Conductor : plain copper wire, stranded. Insulation : PVC compound, 105° C. Triple : three conductors twisted to a triple.TIMF construction : polyester tape above the triple, AL-PES tape over solid tinned copper drain wire, 0,60 mm. Separator : polyester tape.Screen : AL-PES tape over stranded tinned copper drain wire 0,50 mm². Outer sheath : PVC compound, 105° C. Sheath colour : RAL 9005, black or RAL 5015, blue.* Complete information available in the data sheet of this cable.
RE-Yw(St)YwSWAYw-fl-PIMF 105° C - CU/PVC/OSCR/PVC/SWA/PVC - PVC insulated, screened, armoured, PVC sheathed instrumentation cable 300 V ConstructionConductor : plain copper wire, stranded. Insulation : PVC compound, 105° C. PIMF Construction : polyester tape above the pair, AL-PES tape over solid tinned copper drain wire, 0,60 mm. Separator : polyester tape.Screen : AL-PES tape over stranded tinned copper drain wire 0,50 mm². Inner/outer sheath : PVC compound, 105° C. Armour : galvanized round steel wire. Sheath colour : RAL 9005, black or RAL 5015, blue. * Complete information available in the data sheet of this cable.
RE-Yw(St)YwSWAYw-fl 105° C - CU/PVC/OSCR/PVC/SWA/PVC - PVC insulated, screened, armoured, PVC sheathed instrumentation cable 300 V ConstructionConductor : plain copper wire, stranded. Insulation : PVC compound, 105° C. Pair : two conductors twisted to a pair.Lay-up : pairs laid up in layers of optimum pitch.Separator : polyester tape.Screen : AL-PES tape over stranded tinned copper drain wire 0,50 mm². Inner sheath : PVC compound, 105° C. Armour : galvanized round steel wire. Outer sheath : PVC compound, 105° C. Sheath colour : RAL 9005, black or RAL 5015, blue.
RE-Yw(St)YwSWAYw-fl MP 105° C - CU/PVC/OSCR/PVC/SWA/PVC - PVC insulated, screened, armoured, PVC sheathed instrumentation cable 300 V Construction Conductor : plain copper wire, stranded. Insulation : PVC compound, 105° C. Core identification : black / white cores numbered 1-1, 2-2,… Upon request : colour coded according to IEC 60189-2.Lay-up : pairs laid up in layers of optimum pitch.Separator : polyester tape.Screen : AL-PES tape over stranded tinned copper drain wire 0,50 mm². Inner sheath : PVC compound, 105° C. Armour : galvanized round steel wire. Outer sheath : PVC compound, 105° C. Sheath colour : RAL 9005, black or RAL 5015, blue.
RE-Yw(St)YwSWAYw-fl TIMF 105° C - CU/PVC/ISCR/OSCR/PVC/SWA/PVC - PVC screened, armoured, PVC sheathed instrumentation cable 300 V Construction Conductor : plain copper wire, stranded. Insulation : PVC compound, 105° C. TIMF construction : polyester tape above the triple, AL-PES tape over solid tinned copper drain wire, 0,60 mm. Separator : polyester tape.Screen : AL-PES tape. Inner/outer sheath : PVC compound, 105° C. Armour : galvanized round steel wire. Sheath colour : RAL 9005, black or RAL 5015, blue. * Please refer to the data sheet for complete information about this cable.
RE-2X(St)H-PIMF 90° C - CU/XLPE/ISCR/OSCR/LSZH - XLPE insulated, screened, HFFR sheathed instrumentation cable 500 V Construction Conductor : plain copper wire, stranded. Insulation : XLPE compound (RE-2X...). PIMF construction : polyester tape above the pair, AL-PES tape over solid tinned copper drain wire, 0,60 mm.Upon request : stranded 0,50 mm² copper drain wire.Separator : polyester tape.Screen : AL-PES tape over stranded tinned copper drain wire 0,50 mm². Outer sheath : HFFR compound. Sheath colour : RAL 9005, black or RAL 5015, blue. *Please check the data sheet for detailed information.
RE-2X(St)H 90° C - CU/XLPE/OSCR/LSZH - XLPE insulated, screened, HFFR sheathed instrumentation cable 500 V ConstructionConductor : plain copper wire, stranded. Insulation : XLPE compound (RE-2X...). Core identification : black / blue / red cores are numbered (1-1-1, 2-2-2,…). Lay-up : triples laid up in layers of optimum pitch.Separator : polyester tape.Screen : AL-PES tape over stranded tinned copper drain wire 0,50 mm². Outer sheath : HFFR compound. Sheath colour : RAL 9005, black or RAL 5015, blue. *Please check the data sheet for detailed information.
RE-2X(St)H MP 90° C - CU/XLPE/OSCR/LSZH - XLPE insulated, screened, HFFR sheathed instrumentation cable 500 V ConstructionConductor : plain copper wire, stranded. Insulation : XLPE compound (RE-2X...). Core identification : black / blue cores numbered 1-1, 2-2,… Upon request : colour coded according to IEC 60189-2.Pair : two conductors twisted to a pair.Lay-up : pairs laid up in layers of optimum pitch.Separator : polyester tape.Screen : AL-PES tape over stranded tinned copper drain wire 0,50 mm². Outer sheath : HFFR compound. Sheath colour : RAL 9005, black or RAL 5015, blue. *Please check the data sheet for detailed information.
RE-2Y(St)H MP 70° C - CU/PE/OSCR/LSZH - PE insulated, screened, HFFR sheathed instrumentation cable 500 V ConstructionConductor : plain copper wire, stranded. Insulation : PE compound (RE-2Y...). Core identification : black / blue cores numbered 1-1, 2-2,… Upon request : colour coded according to IEC 60189-2.Pair : two conductors twisted to a pair.Lay-up : pairs laid up in layers of optimum pitch.Separator : polyester tape.Screen : AL-PES tape over stranded tinned copper drain wire 0,50 mm². Outer sheath : HFFR compound. Sheath colour : RAL 9005, black or RAL 5015, blue. *Please check the data sheet for detailed information.
RE-2X(St)H-TIMF 90° C - CU/XLPE/ISCR/OSCR/LSZH - XLPE insulated, screened, HFFR sheathed instrumentation cable 500 V Construction Conductor : plain copper wire, stranded. Insulation : XLPE compound (RE-2X...). Triple : three conductors twisted to a triple.TIMF construction : polyester tape above the triple, AL-PES tape over solid tinned copper drain wire, 0,60 mm. Separator : polyester tape.Screen : AL-PES tape over stranded tinned copper drain wire 0,50 mm². Outer sheath : HFFR compound. Sheath colour : RAL 9005, black or RAL 5015, blue. *Please check the data sheet for detailed information.